Condensing gas tankless · Rheem

Rheem RTGH-95DVLN-3 199,900 BTU Natural Gas Condensing Tankless Water Heater

199,900 BTU/h condensing gas tankless, about 8.4 GPM at a 45°F rise

9.5 GPM max199,900 BTU/h~5.4 GPM at 70°F riseNatural gasCondensing, plastic vent

Updated October 2026

The short answer

A sensible condensing gas tankless for houses running 2 showers at once in winter.

Delivers
199,900 BTU/h input.
Watch for
Needs a gas line sized for the load.
Suits
Houses running 2 showers at once in winter.
Max flow (maker)
9.5 GPM
Input (maker)
199,900 BTU/h
Voltage
120 V
Fuel
Natural Gas
Condensing
Condensing
Venting
direct vent
Prices change often; the button shows today's price.

Each button opens this exact model. We may earn a commission on tracked links; it never changes what we publish. Disclosure

What it delivers

The Rheem RTGH-95DVLN-3 199,900 BTU Natural Gas Condensing Tankless Water Heater is a condensing gas tankless with a 199,900 BTU/h burner and a stated maximum flow of 9.5 GPM.

Worked out from its input, it delivers roughly 8.4 GPM when the water only has to rise 45°F, and 5.4 GPM at a 70°F winter rise: 4 showers at 2 GPM in summer, 2 showers at 2 GPM in winter. Size it to your fixtures and climate.

Gas load at full fire: about 193 cubic feet of natural gas an hour. An older half-inch line that already feeds a furnace often can't spare that, so have a gas fitter check the pipe size and run.

As a condensing unit it vents in the plastic pipe (PVC, CPVC or polypropylene) its manual lists and drains an acidic condensate, usually through a neutralizer.

The listing describes its venting as: direct vent.

Other listed details: features: LED Display; material: Stainless Steel; model: RTGH-95DVLN-3; warranty: 1 Year Labor, 15 Year Heat Exchanger, 5 Year Parts.

The listing gives dimensions of 17.7 in (W) x 23.7 in (H), a weight of 59.9 lb and product only in the box.

Warranty, per the listing: 1 Year Labor, 15 Year Heat Exchanger, 5 Year Parts.

Right unit for this house?

Install it when

  • Houses running 2 showers at once in winter
  • Replacing a gas tank heater

Look at another unit when

  • More than 2 winter showers at once
  • Homes without a gas line

Strengths and trade-offs

Strengths

  • 199,900 BTU/h input
  • Up to 9.5 GPM
  • Condensing efficiency

Trade-offs

  • Needs a gas line sized for the load
  • Needs a condensate drain
  • Annual flushing on hard water

Install limits

  • Figures are the maker's or seller's own. Flow at a rise is our estimate from the input; gas, venting and electrical work needs a licensed professional.

Rated performance

Every figure below comes from the source shown in brackets. Where the maker doesn't state something, we say so instead of estimating.

Model numberRTGH-95DVLN-3Retailer
Dimensions (seller)17.7"W x 23.7"HRetailer
Features (seller)LED DisplayRetailer
Voltage120 VRetailer
Max flow (maker)9.5 GPMRetailer
Input (maker)199,900 BTU/hRetailer
Product weight59.9 lbRetailer
MaterialStainless SteelRetailer
Warranty1 Year Labor, 15 Year Heat Exchanger, 5 Year PartsRetailer
FuelNatural GasRetailer
Ventingdirect ventRetailer
CondensingCondensingRetailer

Rival units at this flow

More gas tankless water heaters rated for similar demand

Full gas tankless water heaters spec grid · Every Rheem unit in the catalog

Final verdict

A sensible condensing gas tankless for houses running 2 showers at once in winter.

Buy this unit

Our links open this exact model's product page. Prices and stock change; check what's included before you order.

Prices change often; the button shows today's price.

Each button opens this exact model. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Questions buyers ask

Is the Rheem RTGH-95DVLN-3 199,900 BTU Natural Gas Condensing Tankless Water Heater big enough for two showers?
From its 199,900 BTU/h input we estimate about 8.4 GPM at a 45°F rise and 5.4 GPM at a 70°F rise, so 4 two-GPM showers with mild inlet water and 2 in a cold winter. The maker's flow chart for this model is the final word.
What size gas line does the Rheem RTGH-95DVLN-3 199,900 BTU Natural Gas Condensing Tankless Water Heater need?
At full fire it uses about 193 cubic feet of natural gas an hour. The pipe size depends on the length of the run and every other gas appliance on it; the maker's manual and a licensed gas fitter decide it.